Codebase list libvirt / debian/0.7.1-1 docs / formatdomain.html.in
debian/0.7.1-1

Tree @debian/0.7.1-1 (Download .tar.gz)

formatdomain.html.in @debian/0.7.1-1raw · history · blame

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
<html>
  <body>
    <h1>Domain XML format</h1>

    <ul id="toc"></ul>

    <p>
      This section describes the XML format used to represent domains, there are
      variations on the format based on the kind of domains run and the options
      used to launch them. For hypervisor specific details consult the
      <a href="drivers.html">driver docs</a>
    </p>


    <h2><a name="elements">Element and attribute overview</a></h2>

    <p>
      The root element required for all virtual machines is
      named <code>domain</code>. It has two attributes, the
      <code>type</code> specifies the hypervisor used for running
      the domain. The allowed values are driver specific, but
      include "xen", "kvm", "qemu", "lxc" and "kqemu". The
      second attribute is <code>id</code> which is a unique
      integer identifier for the running guest machine. Inactive
      machines have no id value.
    </p>


    <h3><a name="elementsMetadata">General metadata</a></h3>

    <pre>
      &lt;domain type='xen' id='3'&gt;
        &lt;name&gt;fv0&lt;/name&gt;
        &lt;uuid&gt;4dea22b31d52d8f32516782e98ab3fa0&lt;/uuid&gt;
        ...</pre>

    <dl>
      <dt><code>name</code></dt>
      <dd>The content of the <code>name</code> element provides
	a short name for the virtual machine. This name should
	consist only of alpha-numeric characters and is required
	to be unique within the scope of a single host. It is
	often used to form the filename for storing the persistent
	configuration file. <span class="since">Since 0.0.1</span></dd>
      <dt><code>uuid</code></dt>
      <dd>The content of the <code>uuid</code> element provides
	a globally unique identifier for the virtual machine.
	The format must be RFC 4122 compliant, eg <code>3e3fce45-4f53-4fa7-bb32-11f34168b82b</code>.
	If omitted when defining/creating a new machine, a random
	UUID is generated. <span class="since">Since 0.0.1</span></dd>
    </dl>

    <h3><a name="elementsOS">Operating system booting</a></h3>

    <p>
      There are a number of different ways to boot virtual machines
      each with their own pros and cons.
    </p>

    <h4><a name="elementsOSBIOS">BIOS bootloader</a></h4>

    <p>
      Booting via the BIOS is available for hypervisors supporting
      full virtualization. In this case the BIOS has a boot order
      priority (floppy, harddisk, cdrom, network) determining where
      to obtain/find the boot image.
    </p>

    <pre>
        ...
        &lt;os&gt;
          &lt;type&gt;hvm&lt;/type&gt;
          &lt;loader&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
          &lt;boot dev='hd'/&gt;
        &lt;/os&gt;
        ...</pre>

    <dl>
      <dt><code>type</code></dt>
      <dd>The content of the <code>type</code> element specifies the
	type of operating system to be booted in the virtual machine.
	<code>hvm</code> indicates that the OS is one designed to run
	on bare metal, so requires full virtualization. <code>linux</code>
	(badly named!) refers to an OS that supports the Xen 3 hypervisor
	guest ABI. There are also two optional attributes, <code>arch</code>
	specifying the CPU architecture to virtualization, and <code>machine</code>
	referring to the machine type. The <a href="formatcaps.html">Capabilities XML</a>
	provides details on allowed values for these. <span class="since">Since 0.0.1</span></dd>
      <dt><code>loader</code></dt>
      <dd>The optional <code>loader</code> tag refers to a firmware blob
	used to assist the domain creation process. At this time, it is
	only needed by Xen fully virtualized domains. <span class="since">Since 0.1.0</span></dd>
      <dt><code>boot</code></dt>
      <dd>The <code>dev</code> attribute takes one of the values "fd", "hd",
	"cdrom" or "network" and is used to specify the next boot device
	to consider. The <code>boot</code> element can be repeated multiple
	times to setup a priority list of boot devices to try in turn.
	<span class="since">Since 0.1.3</span>
      </dd>
    </dl>

    <h4><a name="elementsOSBootloader">Host bootloader</a></h4>

    <p>
      Hypervisors employing paravirtualization do not usually emulate
      a BIOS, and instead the host is responsible to kicking off the
      operating system boot. This may use a pseudo-bootloader in the
      host to provide an interface to choose a kernel for the guest.
      An example is <code>pygrub</code> with Xen.
    </p>

    <pre>
        ...
	&lt;bootloader&gt;/usr/bin/pygrub&lt;/bootloader&gt;
	&lt;bootloader_args&gt;--append single&lt;/bootloader_args&gt;
        ...</pre>

    <dl>
      <dt><code>bootloader</code></dt>
      <dd>The content of the <code>bootloader</code> element provides
	a fully qualified path to the bootloader executable in the
	host OS. This bootloader will be run to choose which kernel
	to boot. The required output of the bootloader is dependent
	on the hypervisor in use. <span class="since">Since 0.1.0</span></dd>
      <dt><code>bootloader_args</code></dt>
      <dd>The optional <code>bootloader_args</code> element allows
	command line arguments to be passed to the bootloader.
	<span class="since">Since 0.2.3</span>
	</dd>

    </dl>

    <h4><a name="elementsOSKernel">Direct kernel boot</a></h4>

    <p>
      When installing a new guest OS it is often useful to boot directly
      from a kernel and initrd stored in the host OS, allowing command
      line arguments to be passed directly to the installer. This capability
      is usually available for both para and full virtualized guests.
    </p>

    <pre>
        ...
	&lt;os&gt;
          &lt;type&gt;hvm&lt;/type&gt;
          &lt;loader&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
          &lt;kernel&gt;/root/f8-i386-vmlinuz&lt;/kernel&gt;
          &lt;initrd&gt;/root/f8-i386-initrd&lt;/initrd&gt;
          &lt;cmdline&gt;console=ttyS0 ks=http://example.com/f8-i386/os/&lt;/cmdline&gt;
	&lt;/os&gt;
	...</pre>

    <dl>
      <dt><code>type</code></dt>
      <dd>This element has the same semantics as described earlier in the
	<a href="#elementsOSBIOS">BIOS boot section</a></dd>
      <dt><code>loader</code></dt>
      <dd>This element has the same semantics as described earlier in the
	<a href="#elementsOSBIOS">BIOS boot section</a></dd>
      <dt><code>kernel</code></dt>
      <dd>The contents of this element specify the fully-qualified path
	to the kernel image in the host OS.</dd>
      <dt><code>initrd</code></dt>
      <dd>The contents of this element specify the fully-qualified path
	to the (optional) ramdisk image in the host OS.</dd>
      <dt><code>cmdline</code></dt>
      <dd>The contents of this element specify arguments to be passed to
	the kernel (or installer) at boottime. This is often used to
	specify an alternate primary console (eg serial port), or the
	installation media source / kickstart file</dd>
    </dl>

    <h3><a name="elementsResources">Basic resources</a></h3>

    <pre>
        ...
	&lt;memory&gt;524288&lt;/memory&gt;
	&lt;currentMemory&gt;524288&lt;/currentMemory&gt;
	&lt;memoryBacking&gt;
	  &lt;hugepages/&gt;
        &lt;/memoryBacking&gt;
	&lt;vcpu&gt;1&lt;/vcpu&gt;
	...</pre>

    <dl>
      <dt><code>memory</code></dt>
      <dd>The maximum allocation of memory for the guest at boot time.
	The units for this value are kilobytes (i.e. blocks of 1024 bytes)</dd>
      <dt><code>currentMemory</code></dt>
      <dd>The actual allocation of memory for the guest. This value
	be less than the maximum allocation, to allow for ballooning
	up the guests memory on the fly. If this is omitted, it defaults
	to the same value as the <code>memory<code> element</dd>
      <dt><code>memoryBacking</code></dt>
      <dd>The optional <code>memoryBacking</code> element, may have an
	<code>hugepages</code> element set within it. This tells the
	hypervisor that the guest should have its memory allocated using
	hugepages instead of the normal native page size.</dd>
      <dt><code>vcpu</code></dt>
      <dd>The content of this element defines the number of virtual
	CPUs allocated for the guest OS.</dd>
    </dl>

    <h3><a name="elementsLifecycle">Lifecycle control</a></h3>

    <p>
      It is sometimes necessary to override the default actions taken
      when a guest OS triggers a lifecycle operation. The following
      collections of elements allow the actions to be specified. A
      common use case is to force a reboot to be treated as a poweroff
      when doing the initial OS installation. This allows the VM to be
      re-configured for the first post-install bootup.
    </p>

    <pre>
        ...
	&lt;on_poweroff&gt;destroy&lt;/on_poweroff&gt;
	&lt;on_reboot&gt;restart&lt;/on_reboot&gt;
	&lt;on_crash&gt;restart&lt;/on_crash&gt;
	...</pre>

    <dl>
      <dt><code>on_poweroff</code></dt>
      <dd>The content of this element specifies the action to take when
	the guest requests a poweroff.</dd>
      <dt><code>on_reboot</code></dt>
      <dd>The content of this element specifies the action to take when
	the guest requests a reboot.</dd>
      <dt><code>on_crash</code></dt>
      <dd>The content of this element specifies the action to take when
	the guest crashes.</dd>
    </dl>

    <p>
      Each of these states allow for the same four possible actions.
    </p>

    <dl>
      <dt><code>destroy</code></dt>
      <dd>The domain will be terminated completely and all resources
	released</dd>
      <dt><code>restart</code></dt>
      <dd>The domain will be terminated, and then restarted with
	the same configuration</dd>
      <dt><code>preserve</code></dt>
      <dd>The domain will be terminated, and its resource preserved
	to allow analysis.</dd>
      <dt><code>rename-restart</code></dt>
      <dd>The domain will be terminated, and then restarted with
	a new name</dd>
    </dl>

    <h3><a name="elementsFeatures">Hypervisor features</a></h3>

    <p>
      Hypervisors may allow certain CPU / machine features to be
      toggled on/off.
    </p>

    <pre>
        ...
	&lt;features&gt;
	  &lt;pae/&gt;
	  &lt;acpi/&gt;
	  &lt;apic/&gt;
	&lt;/features&gt;
	...</pre>

    <p>
      All features are listed within the <code>features</code>
      element, omitting a togglable feature tag turns it off.
      The available features can be found by asking
      for the <a href="formatcaps.html">capabilities XML</a>,
      but a common set for fully virtualized domains are:
    </p>

    <dl>
      <dt><code>pae</code></dt>
      <dd>Physical address extension mode allows 32-bit guests
	to address more than 4 GB of memory.</dd>
      <dt><code>acpi</code></dt>
      <dd>ACPI is useful for power management, for example, with
	KVM guests it is required for graceful shutdown to work.
      </dd>
    </dl>

    <h3><a name="elementsTime">Time keeping</a></h3>

    <p>
      The guest clock is typically initialized from the host clock.
      Most operating systems expect the hardware clock to be kept
      in UTC, and this is the default. Windows, however, expects
      it to be in so called 'localtime'.
    </p>

    <pre>
        ...
        &lt;clock offset="localtime"/&gt;
	...</pre>

    <dl>
      <dt><code>clock</code></dt>
      <dd>The <code>sync</code> attribute takes either "utc" or
	"localtime" to specify how the guest clock is initialized
	in relation to the host OS.
      </dd>
    </dl>

    <h3><a name="elementsDevices">Devices</a></h3>

    <p>
      The final set of XML elements are all used to describe devices
      provided to the guest domain. All devices occur as children
      of the main <code>devices</code> element.
      <span class="since">Since 0.1.3</span>
    </p>

    <pre>
        ...
        &lt;devices&gt;
	  &lt;emulator&gt;/usr/lib/xen/bin/qemu-dm&lt;/emulator&gt;
          ...</pre>

    <dl>
      <dt><code>emulator</code></dt>
      <dd>
	The contents of the <code>emulator</code> element specify
	the fully qualified path to the device model emulator binary.
	The <a href="formatcaps.html">capabilities XML</a> specifies
	the recommended default emulator to use for each particular
	domain type / architecture combination.
      </dd>
    </dl>

    <h4><a name="elementsDisks">Hard drives, floppy disks, CDROMs</a></h4>

    <p>
      Any device that looks like a disk, be it a floppy, harddisk,
      cdrom, or paravirtualized driver is specified via the <code>disk</code>
      element.
    </p>

    <pre>
          ...
	  &lt;disk type='file'&gt;
	    &lt;driver name="tap" type="aio"&gt;
	    &lt;source file='/var/lib/xen/images/fv0'/&gt;
	    &lt;target dev='hda' bus='ide'/&gt;
            &lt;encryption type='...'&gt;
              ...
            &lt;/encryption&gt;
	  &lt;/disk&gt;
	  ...</pre>

    <dl>
      <dt><code>disk</code></dt>
      <dd>The <code>disk</code> element is the main container for describing
	disks. The <code>type</code> attribute is either "file" or "block"
	and refers to the underlying source for the disk. The optional
	<code>device</code> attribute indicates how the disk is to be exposed
	to the guest OS. Possible values for this attribute are "floppy", "disk"
	and "cdrom", defaulting to "disk".
	<span class="since">Since 0.0.3; "device" attribute since 0.1.4</span></dd>
      <dt><code>source</code></dt>
      <dd>If the disk <code>type</code> is "file", then the <code>file</code> attribute
	specifies the fully-qualified path to the file holding the disk. If the disk
	<code>type</code> is "block", then the <code>dev</code> attribute specifies
	the path to the host device to serve as the disk. <span class="since">Since 0.0.3</span></dd>
      <dt><code>target</code></dt>
      <dd>The <code>target</code> element controls the bus / device under which the
	disk is exposed to the guest OS. The <code>dev</code> attribute indicates
	the "logical" device name. The actual device name specified is not guaranteed to map to
	the device name in the guest OS. Treat it as a device ordering hint.
	The optional <code>bus</code> attribute specifies the type of disk device
	to emulate; possible values are driver specific, with typical values being
	"ide", "scsi", "virtio", "xen" or "usb". If omitted, the bus type is
	inferred from the style of the device name. eg, a device named 'sda'
	will typically be exported using a SCSI bus.
	<span class="since">Since 0.0.3; <code>bus</code> attribute since 0.4.3;
        "usb" attribute value since after 0.4.4</span></dd>
      <dt><code>driver</code></dt>
      <dd>If the hypervisor supports multiple backend drivers, then the optional
	<code>driver</code> element allows them to be selected. The <code>name</code>
	attribute is the primary backend driver name, while the optional <code>type</code>
	attribute provides the sub-type. <span class="since">Since 0.1.8</span>
      </dd>
      <dt><code>encryption</code></dt>
      <dd>If present, specifies how the volume is encrypted.  See
        the <a href="formatstorageencryption.html">Storage Encryption</a> page
        for more information.
      </dd>
    </dl>

    <h4><a name="elementsUSB">USB and PCI devices</a></h4>

    <p>
      USB and PCI devices attached to the host can be passed through to the guest using
      the <code>hostdev</code> element. <span class="since">since after
      0.4.4 for USB and 0.6.0 for PCI (KVM only)</span>:
    </p>

    <pre>
          ...
	  &lt;hostdev mode='subsystem' type='usb'&gt;
	    &lt;source&gt;
	      &lt;vendor id='0x1234'/&gt;
	      &lt;product id='0xbeef'/&gt;
	    &lt;/source&gt;
	  &lt;/hostdev&gt;
	  ...</pre>
    <p>or:</p>
    <pre>
          ...
	  &lt;hostdev mode='subsystem' type='pci'&gt;
	    &lt;source&gt;
	      &lt;address bus='0x06' slot='0x02' function='0x0'/&gt;
	    &lt;/source&gt;
	  &lt;/hostdev&gt;
	  ...</pre>

    <dl>
      <dt><code>hostdev</code></dt>
      <dd>The <code>hostdev</code> element is the main container for describing
      host devices. For usb device passthrough <code>mode</code> is always
      "subsystem" and <code>type</code> is "usb" for an USB device and "pci"
      for a PCI device..
      <dt><code>source</code></dt>
      <dd>The source element describes the device as seen from the host.
      The USB device can either be addressed by vendor / product id using the
      <code>vendor</code> and <code>product</code> elements or by the device's
      address on the hosts using the <code>address</code> element.
      PCI devices on the other hand can only be described by their
      <code>address</code></dd>
      <dt><code>vendor</code>, <code>product</code></dt>
      <dd>The <code>vendor</code> and <code>product</code> elements each have an
      <code>id</code> attribute that specifies the USB vendor and product id.
      The ids can be given in decimal, hexadecimal (starting with 0x) or
      octal (starting with 0) form.</dd>
      <dt><code>address</code></dt>
      <dd>The <code>address</code> element for USB devices has a
      <code>bus</code> and <code>device</code> attribute to specify the
      USB bus and device number the device appears at on the host.
      The values of these attributes can be given in decimal, hexadecimal
      (starting with 0x) or octal (starting with 0) form.
      For PCI devices the element carries 3 attributes allowing to designate
      the device as can be found with the <code>lspci</code> or
      with <code>virsh nodedev-list</code>. The
      <code>bus</code> attribute allows the hexadecimal values 0 to ff, the
      <code>slot</code> attribute allows the hexadecimal values 0 to 1f, and
      the <code>function</code> attribute allows the hexadecimal values 0 to
      7. There is also an optional <code>domain</code> attribute for the
      PCI domain, with hexadecimal values 0 to ffff, but it is currently
      not used by qemu.</dd>
    </dl>

    <h4><a name="elementsNICS">Network interfaces</a></h4>

    <pre>
          ...
	  &lt;interface type='bridge'&gt;
	    &lt;source bridge='xenbr0'/&gt;
	    &lt;mac address='00:16:3e:5d:c7:9e'/&gt;
	    &lt;script path='vif-bridge'/&gt;
	  &lt;/interface&gt;
	  ...</pre>

    <h5><a name="elementsNICSVirtual">Virtual network</a></h5>

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
      hosts with dynamic / wireless networking configs
      </em></strong>
    </p>

    <p>
      Provides a virtual network using a bridge device in the host.
      Depending on the virtual network configuration, the network may be
      totally isolated, NAT'ing to an explicit network device, or NAT'ing to
      the default route. DHCP and DNS are provided on the virtual network in
      all cases and the IP range can be determined by examining the virtual
      network config with '<code>virsh net-dumpxml [networkname]</code>'.
      There is one virtual network called 'default' setup out
      of the box which does NAT'ing to the default route and has an IP range of
      <code>192.168.22.0/255.255.255.0</code>. Each guest will have an
      associated tun device created with a name of vnetN, which can also be
      overridden with the &lt;target&gt; element.
    </p>

    <pre>
      ...
      &lt;interface type='network'&gt;
        &lt;source network='default'/&gt;
      &lt;/interface&gt;
      ...
      &lt;interface type='network'&gt;
        &lt;source network='default'/&gt;
        &lt;target dev='vnet7'/&gt;
        &lt;mac address="11:22:33:44:55:66"/&gt;
      &lt;/interface&gt;
      ...</pre>

    <h5><a name="elementsNICSBridge">Bridge to to LAN</a></h5>

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
      hosts with static wired networking configs
      </em></strong>
    </p>

    <p>
      Provides a bridge from the VM directly onto the LAN. This assumes
      there is a bridge device on the host which has one or more of the hosts
      physical NICs enslaved. The guest VM will have an associated tun device
      created with a name of vnetN, which can also be overridden with the
      &lt;target&gt; element. The tun device will be enslaved to the bridge.
      The IP range / network configuration is whatever is used on the LAN. This
      provides the guest VM full incoming &amp; outgoing net access just like a
      physical machine.
    </p>

    <pre>
      ...
      &lt;interface type='bridge'&gt;
        &lt;source bridge='br0'/&gt;
      &lt;/interface&gt;

      &lt;interface type='bridge'&gt;
        &lt;source bridge='br0'/&gt;
        &lt;target dev='vnet7'/&gt;
        &lt;mac address="11:22:33:44:55:66"/&gt;
      &lt;/interface&gt;
      ...</pre>

    <h5><a name="elementsNICSSlirp">Userspace SLIRP stack</a></h5>

    <p>
      Provides a virtual LAN with NAT to the outside world. The virtual
      network has DHCP &amp; DNS services and will give the guest VM addresses
      starting from <code>10.0.2.15</code>. The default router will be
      <code>10.0.2.2</code> and the DNS server will be <code>10.0.2.3</code>.
      This networking is the only option for unprivileged users who need their
      VMs to have outgoing access.
    </p>

    <pre>
      ...
      &lt;interface type='user'/&gt;
      ...
      &lt;interface type='user'&gt;
        &lt;mac address="11:22:33:44:55:66"/&gt;
      &lt;/interface&gt;
      ...</pre>


    <h5><a name="elementsNICSEthernet">Generic ethernet connection</a></h5>

    <p>
      Provides a means for the administrator to execute an arbitrary script
      to connect the guest's network to the LAN. The guest will have a tun
      device created with a name of vnetN, which can also be overridden with the
      &lt;target&gt; element. After creating the tun device a shell script will
      be run which is expected to do whatever host network integration is
      required. By default this script is called /etc/qemu-ifup but can be
      overridden.
    </p>

    <pre>
      ...
      &lt;interface type='ethernet'/&gt;
      ...
      &lt;interface type='ethernet'&gt;
        &lt;target dev='vnet7'/&gt;
        &lt;script path='/etc/qemu-ifup-mynet'/&gt;
      &lt;/interface&gt;
      ...</pre>

    <h5><a name="elementsNICSMulticast">Multicast tunnel</a></h5>

    <p>
      A multicast group is setup to represent a virtual network. Any VMs
      whose network devices are in the same multicast group can talk to each
      other even across hosts. This mode is also available to unprivileged
      users. There is no default DNS or DHCP support and no outgoing network
      access. To provide outgoing network access, one of the VMs should have a
      2nd NIC which is connected to one of the first 4 network types and do the
      appropriate routing. The multicast protocol is compatible with that used
      by user mode linux guests too. The source address used must be from the
      multicast address block.
    </p>

    <pre>
      ...
      &lt;interface type='mcast'&gt;
        &lt;source address='230.0.0.1' port='5558'/&gt;
      &lt;/interface&gt;
      ...</pre>

    <h5><a name="elementsNICSTCP">TCP tunnel</a></h5>

    <p>
      A TCP client/server architecture provides a virtual network. One VM
      provides the server end of the network, all other VMS are configured as
      clients. All network traffic is routed between the VMs via the server.
      This mode is also available to unprivileged users. There is no default
      DNS or DHCP support and no outgoing network access. To provide outgoing
      network access, one of the VMs should have a 2nd NIC which is connected
      to one of the first 4 network types and do the appropriate routing.</p>

    <pre>
      ...
      &lt;interface type='server'&gt;
        &lt;source address='192.168.0.1' port='5558'/&gt;
      &lt;/interface&gt;
      ...
      &lt;interface type='client'&gt;
      &lt;source address='192.168.0.1' port='5558'/&gt;
      &lt;/interface&gt;
      ...</pre>

    <h5><a name="elementsNICSModel">Setting the NIC model</a></h5>

    <pre>
      ...
      &lt;interface type='network'&gt;
        &lt;source network='default'/&gt;
        &lt;target dev='vnet1'/&gt;
        <b>&lt;model type='ne2k_pci'/&gt;</b>
      &lt;/interface&gt;
      ...</pre>

    <p>
      For hypervisors which support this, you can set the model of
      emulated network interface card.
    </p>

    <p>
      The values for <code>type</code> aren't defined specifically by
      libvirt, but by what the underlying hypervisor supports (if
      any).  For QEMU and KVM you can get a list of supported models
      with these commands:
    </p>

<pre>
qemu -net nic,model=? /dev/null
qemu-kvm -net nic,model=? /dev/null
</pre>

    <p>
      Typical values for QEMU and KVM include:
      ne2k_isa i82551 i82557b i82559er ne2k_pci pcnet rtl8139 e1000 virtio
    </p>

    <h4><a name="elementsInput">Input devices</a></h4>

    <p>
      Input devices allow interaction with the graphical framebuffer in the guest
      virtual machine. When enabling the framebuffer, an input device is automatically
      provided. It may be possible to add additional devices explicitly, for example,
      to provide a graphics tablet for absolute cursor movement.
    </p>

    <pre>
          ...
	  &lt;input type='mouse' bus='usb'/&gt;
	  ...</pre>

    <dl>
      <dt><code>input</code></dt>
      <dd>The <code>input</code> element has one mandatory attribute, the <code>type</code>
	whose value can be either 'mouse' or 'tablet'. The latter provides absolute
	cursor movement, while the former uses relative movement. The optional
	<code>bus</code> attribute can be used to refine the exact device type.
	It takes values "xen" (paravirtualized), "ps2" and "usb".</dd>
    </dl>


    <h4><a name="elementsGraphics">Graphical framebuffers</a></h4>

    <p>
      A graphics device allows for graphical interaction with the
      guest OS. A guest will typically have either a framebuffer
      or a text console configured to allow interaction with the
      admin.
    </p>

    <pre>
          ...
	  &lt;graphics type='vnc' port='5904'/&gt;
	  ...</pre>

    <dl>
      <dt><code>graphics</code></dt>
      <dd>The <code>graphics</code> element has a mandatory <code>type</code>
	attribute which takes the value "sdl" or "vnc". The former displays
	a window on the host desktop, while the latter activates a VNC server.
        The former accepts 3 optional arguments: a <code>display</code>
        attribute for the display to use, an <code>xauth</code> attribute for
        the authentication identifier, and an optional <code>fullscreen</code>
        attribute accepting values 'yes' or 'no'.
	If the latter is used the <code>port</code> attribute specifies the TCP
	port number (with -1 as legacy syntax indicating that it should be
	auto-allocated). The <code>autoport</code> attribute is the new
	preferred syntax for indicating autoallocation of the TCP port to use.
	The <code>listen</code> attribute is an IP address for the server to
	listen on. The <code>passwd</code> attribute provides a VNC password
	in clear text. The <code>keymap</code> attribute specifies the keymap
	to use.</dd>
    </dl>

    <h4><a name="elementsConsole">Consoles, serial &amp; parallel devices</a></h4>

    <p>
      A character device provides a way to interact with the virtual machine.
      Paravirtualized consoles, serial ports and parallel ports are all
      classed as character devices and so represented using the same syntax.
    </p>

    <pre>
        ...
        &lt;parallel type='pty'&gt;
	  &lt;source path='/dev/pts/2'/&gt;
	  &lt;target port='0'/&gt;
        &lt;/parallel&gt;
        &lt;serial type='pty'&gt;
	  &lt;source path='/dev/pts/3'/&gt;
	  &lt;target port='0'/&gt;
        &lt;/serial&gt;
        &lt;console type='pty'&gt;
	  &lt;source path='/dev/pts/4'/&gt;
	  &lt;target port='0'/&gt;
        &lt;/console&gt;
        &lt;/devices&gt;
      &lt;/domain&gt;</pre>


    <dl>
      <dt><code>parallel</code></dt>
      <dd>Represents a parallel port</dd>
      <dt><code>serial</code></dt>
      <dd>Represents a serial port</dd>
      <dt><code>console</code></dt>
      <dd>Represents the primary console. This can be the paravirtualized
	console with Xen guests, or duplicates the primary serial port
	for fully virtualized guests without a paravirtualized console.</dd>
      <dt><code>source</code></dt>
      <dd>The attributes available for the <code>source</code> element
	vary according to the <code>type</code> attribute on the parent
	tag. Allowed variations will be described below</dd>
      <dt><code>target</code></dt>
      <dd>The port number of the character device is specified via the
	<code>port</code> attribute, numbered starting from 1. There is
	usually only one console device, and 0, 1 or 2 serial devices
	or parallel devices.
    </dl>

    <h5><a name="elementsCharSTDIO">Domain logfile</a></h5>

    <p>
      This disables all input on the character device, and sends output
      into the virtual machine's logfile
    </p>

    <pre>
      ...
      &lt;console type='stdio'&gt;
        &lt;target port='1'&gt;
      &lt;/console&gt;
      ...</pre>


    <h5><a name="elementsCharFle">Device logfile</a></h5>

    <p>
      A file is opened and all data sent to the character
      device is written to the file.
    </p>

    <pre>
      ...
      &lt;serial type="file"&gt;
        &lt;source path="/var/log/vm/vm-serial.log"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharVC">Virtual console</a></h5>

    <p>
      Connects the character device to the graphical framebuffer in
      a virtual console. This is typically accessed via a special
      hotkey sequence such as "ctrl+alt+3"
    </p>

    <pre>
      ...
      &lt;serial type='vc'&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharNull">Null device</a></h5>

    <p>
      Connects the character device to the void. No data is ever
      provided to the input. All data written is discarded.
    </p>

    <pre>
      ...
      &lt;serial type='null'&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharPTY">Pseudo TTY</a></h5>

    <p>
      A Pseudo TTY is allocated using /dev/ptmx. A suitable client
      such as 'virsh console' can connect to interact with the
      serial port locally.
    </p>

    <pre>
      ...
      &lt;serial type="pty"&gt;
        &lt;source path="/dev/pts/3"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <p>
      NB special case if &lt;console type='pty'&gt;, then the TTY
      path is also duplicated as an attribute tty='/dev/pts/3'
      on the top level &lt;console&gt; tag. This provides compat
      with existing syntax for &lt;console&gt; tags.
    </p>

    <h5><a name="elementsCharHost">Host device proxy</a></h5>

    <p>
      The character device is passed through to the underlying
      physical character device. The device types must match,
      eg the emulated serial port should only be connected to
      a host serial port - don't connect a serial port to a parallel
      port.
    </p>

    <pre>
      ...
      &lt;serial type="dev"&gt;
        &lt;source path="/dev/ttyS0"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharPipe">Named pipe</a></h5>

    <p>
      The character device writes output to a named pipe. See pipe(7) for
      more info.
    </p>

    <pre>
      ...
      &lt;serial type="pipe"&gt;
        &lt;source path="/tmp/mypipe"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharTCP">TCP client/server</a></h5>

    <p>
      The character device acts as a TCP client connecting to a
      remote server.
    </p>

    <pre>
      ...
      &lt;serial type="tcp"&gt;
        &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
        &lt;protocol type="raw"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <p>
      Or as a TCP server waiting for a client connection.
    </p>

    <pre>
      ...
      &lt;serial type="tcp"&gt;
        &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
        &lt;protocol type="raw"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <p>
      Alternatively you can use telnet instead of raw TCP.
    <p>

    <pre>
      ...
      &lt;serial type="tcp"&gt;
        &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
        &lt;protocol type="telnet"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...
      &lt;serial type="tcp"&gt;
        &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
        &lt;protocol type="telnet"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharUDP">UDP network console</a></h5>

    <p>
      The character device acts as a UDP netconsole service,
      sending and receiving packets. This is a lossy service.
    </p>

    <pre>
      ...
      &lt;serial type="udp"&gt;
        &lt;source mode="bind" host="0.0.0.0" service="2445"/&gt;
        &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>

    <h5><a name="elementsCharUNIX">UNIX domain socket client/server</a></h5>

    <p>
      The character device acts as a UNIX domain socket server,
      accepting connections from local clients.
    </p>

    <pre>
      ...
      &lt;serial type="unix"&gt;
        &lt;source mode="bind" path="/tmp/foo"/&gt;
        &lt;target port="1"/&gt;
      &lt;/serial&gt;
      ...</pre>


    <h4><a name="elementsSound">Sound devices</a></h4>

    <p>
      A virtual sound card can be attached to the host via the
      <code>sound</code> element. <span class="since">Since 0.4.3</span>
    </p>

    <pre>
      ...
      &lt;sound model='es1370'/&gt;
      ...</pre>

    <dl>
      <dt><code>sound</code></dt>
      <dd>
        The <code>sound</code> element has one mandatory attribute,
        <code>model</code>, which specifies what real sound device is emulated.
        Valid values are specific to the underlying hypervisor, though typical
        choices are 'es1370', 'sb16', and 'ac97'
        (<span class="since">'ac97' only since 0.6.0</span>)
      </dd>
    </dl>

    <h2><a name="examples">Example configs</a></h2>

    <p>
      Example configurations for each driver are provide on the
      driver specific pages listed below
    </p>

    <ul>
      <li><a href="drvxen.html#xmlconfig">Xen examples</a></li>
      <li><a href="drvqemu.html#xmlconfig">QEMU/KVM examples</a></li>
    </ul>
  </body>
</html>